Protect the environment and your premises!

Install cameras, power them without electricity and place in any location. Just add them to your IT network.


  • Environmental Benefits

  • Environmental Summary

Install cameras anywhere without

electricity!

IP cameras or Analog cameras with Video

Converters can be added to your IT network

by a network cable.  No electricity supply is

required, therefore you save installation and

running costs as well as reduce your carbon

footprint.


Dispoal Warranty included

Both appliances are WEEE compliant and

include a Disposal Warranty. This means that

when your Soratek appliance is no longer

required it will disposed of by the manufacturer

in an environmentally responsible way. 

Monitor premises from any location

Save time and travel costs by monitoring

premises from any remote location using the internet.

1u appliance


Operating Temperature 10º C to 35º C (50º F to 90º F) with the maximum rate of change not to exceed 10°C per hour


Non-Operating Temperature -40°C to +70°C


Non-Operating Humidity 90%, non-condensing @ 28°C


Acoustic noise Sound Pressure: 55 dBA (Rack mount) in an idle state at typical office ambient temperature. (23 +/- degrees C)


Sound Power: 7.0 BA in an idle state at typical

office ambient temperature. (23 +/- 2 degrees C)


Shock, operating Half sine, 2 g peak, 11 mSec


Shock, unpackaged Trapezoidal, 25 g, velocity

change 136 inches/sec (?40 lbs to > 80 lbs)


Shock, packaged Non-palletized free fall in height 24 inches (?40 lbs to > 80 lbs)


Vibration, unpackaged 5 Hz to 500 Hz, 2.20 g RMS random


Shock, operating Half sine, 2 g peak, 11 mSec

ESD +/-15kV except I/O port +/-8KV per Intel Environmental test specification


System Cooling Requirement in BTU/Hr -  2901 BTU/hour

2u appliance


Operating Temperature +10°C to +35°C with the maximum rate of change not to exceed 10°C per hour


Non-Operating Temperature -40°C to +70°C


Non-Operating Humidity 90%, non-condensing @ 28°C


Acoustic noise Sound Pressure: 55 dBA (Rack mount) in an idle state at typical office ambient temperature. (23 +/- degrees C)


Sound Power: 7.0 BA in an idle state at typical

office ambient temperature. (23 +/- 2 degrees C)


Shock, operating Half sine, 2 g peak, 11 mSec


Shock, unpackaged Trapezoidal, 25 g, velocity change 136 inches/sec


Shock, packaged Non-palletized free fall in height 24 inches (?40 lbs to < 80 lbs)


Vibration, unpackaged 5 Hz to 500 Hz, 2.20 g RMS random


Shock, operating Half sine, 2 g peak, 11 mSec

ESD +/-15kV except I/O port +/-8KV per Intel Environmental test specification


System Cooling Requirement in BTU/Hr - 3264 BTU/hour






Did you know?

IP devices do not require electricity. They are powered via PoE (Power over Ethernet).


Connect an IP device such as an IP camera to