1u appliance
Operating Temperature 10º C to 35º C (50º F to 90º F) with the maximum rate of change not to exceed 10°C per hour
Non-Operating Temperature -40°C to +70°C
Non-Operating Humidity 90%, non-condensing @ 28°C
Acoustic noise Sound Pressure: 55 dBA (Rack mount) in an idle state at typical office ambient temperature. (23 +/- degrees C)
Sound Power: 7.0 BA in an idle state at typical
office ambient temperature. (23 +/- 2 degrees C)
Shock, operating Half sine, 2 g peak, 11 mSec
Shock, unpackaged Trapezoidal, 25 g, velocity
change 136 inches/sec (?40 lbs to > 80 lbs)
Shock, packaged Non-palletized free fall in height 24 inches (?40 lbs to > 80 lbs)
Vibration, unpackaged 5 Hz to 500 Hz, 2.20 g RMS random
Shock, operating Half sine, 2 g peak, 11 mSec
ESD +/-15kV except I/O port +/-8KV per Intel Environmental test specification
System Cooling Requirement in BTU/Hr - 2901 BTU/hour | 2u appliance
Operating Temperature +10°C to +35°C with the maximum rate of change not to exceed 10°C per hour
Non-Operating Temperature -40°C to +70°C
Non-Operating Humidity 90%, non-condensing @ 28°C
Acoustic noise Sound Pressure: 55 dBA (Rack mount) in an idle state at typical office ambient temperature. (23 +/- degrees C)
Sound Power: 7.0 BA in an idle state at typical
office ambient temperature. (23 +/- 2 degrees C)
Shock, operating Half sine, 2 g peak, 11 mSec
Shock, unpackaged Trapezoidal, 25 g, velocity change 136 inches/sec
Shock, packaged Non-palletized free fall in height 24 inches (?40 lbs to < 80 lbs)
Vibration, unpackaged 5 Hz to 500 Hz, 2.20 g RMS random
Shock, operating Half sine, 2 g peak, 11 mSec
ESD +/-15kV except I/O port +/-8KV per Intel Environmental test specification
System Cooling Requirement in BTU/Hr - 3264 BTU/hour |